​MONITORING




MAKE


MODELSCT'SCLSMAKE


SCHNEIDER


DM 6100RISHABH1%ELTRAK


RISHABH


EM 6400
0.5%SCHNEIDER


TRINITY


ELF 3259




PM 810





INDICATIONS



MAKES

TYPE
INDICATIONS
INDICATIONS


TECHNIC

22.5Φ -1PH 240 V
O/P PHASES
EARTH FAULT TRIP


ABB



OVER TEMP
I/C CB STATUS

SCHNEIDER



BMS -PFC
O/G CB STATUS


VAISHNAO



CHANGE-OVER SWITCH STATUS




ITEM

 

MAKEPOLERELEASEOPTIONALS


MCB


ABB1PTMD
AUX. CONTACT


MCCB


SCHNEIDER3PTMA
ROTARY HANDLE


ABB


HPL-SOCOMEC4PMICROPROCESSOR BASED
UV COIL


TVSS


OBO-BETTERMAN


MOE


EFR


ASCO

KEY LOCK


VMR


MINILEC




ELECTRICAL SPECIFICATIONS



VOLTAGE NOMINAL

CONFIGU-RATION
VECTOR GROUP
TAPPINGS
FREQUENCY
415V 3Ǿ 3W
3PDSDYn11

​ NOM.AND +/- 5 %


50HZ
415V 3Ǿ 4W
3PDDDYn1

NOM.AND +/- 2.5 - 5 % FOR RATINGS UPTO 100 KVA ONLY
60HZ
415V 2Ǿ 2W
3PDzzSYy0

NO ADDL. TAPPINGS FOR ALUM WOUND ABOVE 250 KVA


230V 1Ǿ L-N

3P-1P(VEE)Dd0
IMPEDANCE
SHIELDING

1P-1PDZn0
<2.5%

​DUAL GALVANIC SHIELDING,CMRR 40-50dB


PROTECTIONS



OL & SC by MCCB

BUILT IN Earth Fault 
GLASS CATRIDGE FUSE
THROUGH TVSS
Audio visible alarm with accept

OL & SC by MCB
External Earth Fault With CBCT & shunt Release
MCB C CURVE
Audio visible alarm PFC FOR BMS


SWITCHGEAR


APPLICATION



STORAGE  TEMP
 OPERATING TEMP 
 RELATIVE HUMIDITY 
ALTITUDE
I/P OF UPS
0-45 DEG. C.
0 - 50 DEG. C

UP TO 95% (Non Condensing)
< 1000 Meter above sea level

O/P OF UPS






BYPASS





K-RATING

WINDING MATERIAL

INSULATION CLASS
CORE LAMINATION
CONSTRUCTION
K1
ALUMINIUM
CLASS HCRGO-MOH/M3/M4/M5/M6 MITER
MULTI STEP LAP / RIGHT ANGLE STRIP   ASSEMBLY


K4


COPPER
CRNGO-M250/M270


K13


ALUMINIUM FOIL
TYPE `


K20




MITRE/STRIP



CAPACITY RANGE IN KVA


10-15-20-30-40-50-60-70-80-9​0-100-125-150-160-180-200-225-250-275-300-350-400-500-600



STANDARDS



AS PER APPLICABLE CLAUSES OF IS 2026-PART I & II-2010 & 2011, IS-11171, UL 1561/ ANSI 57.110 OVERSIZING GUIDELINES ONLY


GENERAL SPECIFICATIONS


BARE-ISO-TXRISO-TXR-ENCLOSEDPDU-WITH-ISO-TXRAUTO-TXR-ENCLOSEDVEE-TXR-ENCLOSED


PRODUCT-RANGE



DATA CENTER POWER SOLUTIONS <<<<< UPS POWER ACCESORIES <<<<< DATA CENTER POWER SOLUTIONS



UTILITY SOCKET

PANEL LIGHTPF CAPACITORS WITH PROTN MCBINTERCONNECTING CABLESPACE HEATER WITH THERMOSTATSPHASE FAILURE PROTECTION


FEATURES OFFERED


DUAL SOURCE AUTOSELECTOR MODULE / PANEL 

OPTIONALS


PANEL DETAILSMATERIALS


PANEL DIMENSIONS


CABLE ENTRYCOLOUR
WXDXHFRAME:2/2.5CRCA


BOTTOM IN BOTTOM OUT


POWDER COATED AS PER REQUIRED COLOUR


OPTIONAL BASE FRAME


DOOR:1.6MM
TOP IN TOP OUT


OPTIONAL ANTIVIBRATION PADS


COVERS:1.2/1.6MM


IP


COOLING


FAN MAKEFAN SIZEFAN CONTROL THERMOSTATS
20/21


AIR NATURAL UPTO 100KVA


REXNORD 6"80 DEG C 3 NOS


AIR NATURALWITH FANSABOVE 100KVA



160 DEG C 3 NOS

    AUTO PHASE               SEQ CORRECTION           MODULE/PANEL

SOFT-START

                           Copyright@2014 Datsons Electronics Pvt.Ltd .                                                                                              All rights reserved .    Email:- sales@datsons.com;contact@datsons.com

PANEL DETAILS


​BCPM